ADC ADView 2 Modular Diagnostic Station
A truly modular diagnostic station that grows with your needs. Each vital signs monitor configuration has a Blood Pressure base unit. From there, you can choose to add-on modules for Temperature, ChipOx Nellcor or Masimo SET, and we will ship your Adview 2 Diagnostic Station fully configured and ready to to. You can add on new modules and accessories in the field, anytime, as you need them. Our user-expandable, connect-and-go construction makes upgrading effortless.
Features for the Adview2 Vital Signs Monitor
- Clinical-grade Advantage™ BP technology from SunTech Medical
- Contemporary, compact design with an integrated handle and easy-to-read display
- Manual blood pressure mode for real-time verification
- Customizable average mode options
- Next-generation EMR ready with HL7 messaging for electronic data transfer
- Network enabled with built-in Ethernet or optional Wi-Fi
- Lithium-ion power for longer-lasting battery life and a lighter weight
- Built-in memory with up to 99 charting sessions
- New Pediatric Mode to ensure accurate measurements for younger patients
- Firmware upgradeable
Availability for the Adview 2 Modular Diagnostic Station
| Configuration | Includes | Model No. |
| ADView 2 BP | Blood pressure base unit | 9005BP |
| ADView 2 BP/Temp | Blood pressure base unit with temperature module | 9005BPTO |
| ADView 2 BP/SpO2 | Blood pressure base unit with ChipOx Nellcor-compatible SpO2 module | 9005BPS |
| ADView 2 BP/SpO2/Temp | Blood pressure base unit with ChipOx Nellcor-compatible SpO2 module and temperature module | 9005BPSTO |
| ADView 2 BP/Masimo SET | Blood pressure base unit with Masimo SET SpO2 module | 9005BPSM |
| ADView 2 BP/Masimo SET/Temp | Blood pressure base unit with Masimo SET SpO2 module and temperature module | 9005BPSMTO |
Get Accessories for the Adview 2 Vital Signs Monitor
| Blood Pressure Cuff Options | ![]() |
| Networking & Calibration Accessories | ![]() |
| Finger Sensors for SpO2 / Pulse Ox | ![]() |
Technical Specs
| SpO2 | |
|---|---|
| Saturation Normal (no motion): | 70-100%Arms ± 2% |
| Saturation Motion: | N/A |
| Low Perfusion: | N/A |
| Pulse Heart rate: | 20-300 BPM: ±3 BPM |
| Pulse Heart rate w/motion: | 20-300 BPM: ±3 BPM |
| Temperature | |
| Temperature Accuracy: | Quick Mode (Oral): ± 0.3°C |
| Temperature Accuracy: | Std. Mode (Aux/Rectal): ± 0.1°C |
| Temperature Accuracy: | Direct Mode ± 0.1°C |
| Response Time: | 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode) |
| Resolution: | 0.1°C |
| Blood Pressure | |
| Range: | Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric). Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric) Heart Rate: 30-220 BPM (beats per minute) |
| Accuracy (BP): | Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation). |
| General Specifications | |
| Conditions for Use: | Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below. |
| Storage: | -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above. |
| Power: | Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector. |
| Battery: | Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner |
| Calibration: | The accuracy of cuff -pressure transducers/indicators should be verified bi-annually. |
| Safety Systems: | Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds. |
| Dimensions: | Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D |
| Standards: | ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013 |
| Classifications: | Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE |
| Ingress of liquid: | Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529. |
| Limited Warranty | |
| Main unit: SpO2 modules: Temp modules: |
3 years |
| Blood Pressure Cuffs: | 2 years |
| Battery: | 1 year |
| Accessories (SpO2 sensors, temp probes, BP hose, etc): |
90 days |
| Software | |
| ADView® 2 Driver for Windows - 32 bit | Download |
| ADView® 2 Driver for Windows - 64 bit | Download |
It All Begins with Blood Pressure
The ADC ADView 2 easily captures automated blood pressure measurements at the touch of a button. Our non-invasive blood pressure base unit module uses the oscillometric method, with both pulse rate and the mean arterial blood pressure (MAP) displayed in about 30 seconds. With seven available cuff sizes, ranging from child to thigh, the ADView 2 can be used for patients ages three and older. Adult Plus and Large Adult Plus cuffs come standard.
Manual mode option for added versatility
Our original ADView was the first diagnostic station to offer a manual mode. It was an innovation developed even earlier for our e-sphyg II, allowing you to capture blood pressure with your stethoscope using the traditional auscultatory method without changing cuffs. Manual mode provides important versatility for your patients with arrhythmias or other complex needs.
New, customizable averaging protocol.
With the ADView 2, we also offer a user-definable averaging mode, with setting options ranging from two to five readings as well as start and interval delays. Averaging is recognized as a key component of accurate blood pressure measurement and was used in the recent SPRINT trial conducted by the National Institute of Health.
Blood pressure base unit includes: Rechargeable lithium-ion battery; U.S. power cord; 10-foot length of tubing; Adult Plus and Large Adult Plus cuffs; Mini-USB to USB cable; Quick Start Guide; Quick Reference Guide.
Temperature Module
Add a Covidien Filac™ 3000 thermometry module to your ADView 2 for an oral or axillary temperature reading in as little as four seconds. The module features both Fahrenheit and Celsius scales, switchable with the touch of a button, a Cold Mode for lower ranges, and a built-in, color-coded storage well for the probe. An optional color-coded rectal chamber and probe is also available.
Temperature module includes: Oral/axillary probe and well (blue) and box of 20 probe covers.
Pulse Oximetry Module
Add a pulse oximetry module to your ADView 2 to measure oxygen saturation of arterial blood flow in about 10 seconds. The ChipOx Nellcor™-compatible SpO2 module displays pulse rate signal strength during measurement, and comes with a reusable finger clip sensor and 8-foot cable. An optional pediatric/multi-site sensor is also available. Alternatively, choose the Masimo SET® SpO2 module upgrade.
SpO2 module includes: Adult finger sensor and 8-foot extension cable.
Choose Now or Choose Later
The ADView 2 is still the only truly modular diagnostic station that grows with your needs. Choose temperature or pulse oximetry options at the time of purchase and we’ll ship your ADView 2 fully configured and ready to go. Or add new modules in the field, anytime, as you need them. Our user-expandable, connect-and-go construction makes upgrading effortless.
ADView® 2: Measuring Blood Pressure, Temperature, and Pulse Oximetry
ADView® 2: Taking Automatic and Manual Blood Pressure Measurements